Functional characteristics
Operating concepts
Item No.: 099-004877-EWM01
31
5.2.2
JOB operation (JOB 1 to 7)
You can select, change and save the required welding parameters for recurring welding tasks (JOBs) in
up to 7 JOBs (JOB 1 to JOB 7).
5.2.2.1
Displaying and changing the JOB number
Operating
element
Action Result
Display
X x
Select JOB display
JOB number
Change the JOB number
JOB number
1 x
If the display switchover is pressed or if there is
no keyboard input for 5 seconds, the new JOB
will be active
JOB number
The procedure for setting welding tasks is the same as described under "Manual, standard
operation (JOB 0)". The "Alternating current balance (TIG AC)" and "Tungsten electrode
diameter/Ignition optimisation" rotary dials are the exception. These welding parameters are set in
JOB 1 to 7 in the function sequence (the signal lights of the same names indicate selection).
A JOB can only be switched if no welding current is flowing.
The up-slope and down-slope times can be set separately for non-latched and latched.