Commissioning
PC interface
Item No.: 099-004877-EWM01
73
6.10.1.1
Selection and adjustment
Operating
element
Action Result
Select JOB numberSignal light
comes on
Select JOB "0" (synchronisation takes place in JOB 0 only)
Select AC welding with corresponding current output wave
Square current output wave form
Trapezoidal current output wave form
Sinusoidal current output wave form
Turn the "Alternating current frequency (TIG AC)" rotary dial to the left as
far as it will go
Signal light
Netsyn.
comes on
6.11
PC interface
The welding machine/PC connection may only ever be made using interface SECINT X10
The SECINT X10 interface should be connected as closely as possible to the PC.
(If this is not observed, the PC may be damaged by high frequency ignition pulses)
Observe the "TETRIX PCT 300" operating instructions.