Functional characteristics
Advanced settings
60
Item No.: 099-004877-EWM01
5.6.2
TIG non-latched operating mode, C version
Operating
element
Action Result
Display
0
1
Switch off the welding machine
-
Press and hold key button
-
Switch on the welding machine
Select Configuration menu item "cFG"
The parameter that can be changed and the associated value blink alternately in the display.
Hold until menu item "2tc" (TIG non-latched C version) is
displayed
Switch TIG non-latched C version operating mode to “on”
To switch off = "off"
Select Configuration menu item "cFG" (deselection)
Select Configuration menu item "Eit" (deselection)
1 x
Deselection "Eit" (Exit)
Welding machine is re-initialised