Sequence:
• Press and hold torch trigger 1.
• The gas pre-flow time elapses.
• HF ignition pulses jump from the electrode to the workpiece, the arc ignites.
• The welding current flows and immediately assumes the value set for the ignition current I
start
.
• HF is switched off.
• The welding current increases in the adjusted up-slope time to the main current AMP.
The process ends when the set SpotArc time elapses or if the torch trigger is released
prematurely.
spotArc/pulse variants table:
Process Pulse
variants
Automated pulses (factory setting)
(lights up in green)
Pulses (thermal pulses)
(lights up in red)
kHz pulse (metallurgic pulses)
TIG DC
No pulses
(lights up in green)
Pulses (thermal pulses)
AC special
TIG AC
No pulses
The up-slope and down-slope times should be set to “0” to achieve an effective result.