Functional characteristics
Advanced settings
62
Item No.: 099-004877-EWM01
5.6.4.1
Selection and adjustment
Operating
element
Action Result
Display
Switch off the welding machine
-
Press and hold key button
-
Switch on welding machine
Select Configuration menu item "cFG"
The parameter that can be changed and the associated value blink alternately in the display.
1 x
Hold until "SEt" menu item is displayed
Select the operating mode
Pro = percentage current setting (1% to 200%)
Abs = absolute current setting (Imin to Imax)
Select Configuration menu item "cFG" (deselection)
Select Configuration menu item "Eit" (deselection)
1 x
Deselection "Eit" (Exit)
Welding machine is re-initialised