8) Parameter group 100: Basic parameter
0:
Target frequency / Parameter (
F
xxx)
1:
Jog modus via keypad - HF-0
2:
Target motor speed (rpm)
4:
DC-voltage
F132
Display: Selection of operating
8:
PID control feed back
16: Heatsink temperature
Default setting:
parameters to display during „STOP“ status
32: Counter
0+2+4
=
6
(Motor stopped)
64:
PID set-point
128: Reserved
256: Reserved
512: Torge control reference
1024: Reserved
2048: Reserved
With inverter in STOP mode, the display will always show the target frequency - flashing
Following table shows the units and display-mode for various parameters:
Motorspeed (rpm):
(
NNNN
)
integer value
– the decimal point indicates values above
9999. Motor Current
A (A.A)
Motor-Voltage:
U (VVV)
Counter status:
(
ZZZZ
)
DC-Voltage:
u (VVV)
Heatsink temperature:
H (TTT)
Calculated speed
L(sss)
. Decimal point to indicate values above 999, two decimal points for values above
9999 PID controller Set-Point (normalized):
(o*.*)
PID Feed-Back (normalized):
(b *.*)
Motor-Power (normalized):
(x.x)
Motor-Torque (normalized):
(m.m)
Single phase inverter size E1 (0.2 - 0.75KW) do not have temperature indication.
Parameter, for calculated speed indication (display)
F133
Transmission ratio
Range: 0.10 - 200.0
Default setting: 1.00
F134
Pulley diameter
0.001
– 1.000 (m)
Default setting: 0.001
Example: Max. Frequency
F111=50.00Hz
, number of poles
F804=4
, transmission ration
F133=1.00
, pulley diameter R=0.05m
(
F134=0,05
), calculation result: pulley circumference: 2πr =2×3.14×0.05=0.314 (meter), shaft speed: 60×frequency / (number
of poles × transmission ratio) = 60×50/ (2×1.00) =1500rpm. For linear speed: speed (rpm) × pulley circumference =
1500×0.314=471(meter/second)
E2000+_Rev.02 -E- SOFT Rev. 5.09
- 37 -
© 2016-06-KPP-EURADRIVES EUROPE GmbH
Содержание E2000-0004 S2B
Страница 14: ...2 Product data product power range E2000 _Rev 02 E SOFT Rev 5 09 12 2016 06 KPP EURADRIVES EUROPE GmbH...
Страница 24: ...2016 06 KPP EURADRIVES EUROPE GmbH...
Страница 27: ...E2000 _Rev 02 D SOFT Rev 5 09 22 2016 06 KPP EURADRIVES EUROPE GmbH...
Страница 47: ...2016 06 KPP EURADRIVES EUROPE GmbH...
Страница 49: ...2016 06 KPP EURADRIVES EUROPE GmbH...
Страница 55: ...2016 06 KPP EURADRIVES EUROPE GmbH...
Страница 63: ...2016 06 KPP EURADRIVES EUROPE GmbH...
Страница 72: ...2016 06 KPP EURADRIVES EUROPE GmbH...
Страница 75: ...17 Parameter group A00 PID controller setup E2000 _Rev 02 E SOFT Rev 5 09 65 2016 06 KPP EURADRIVES EUROPE GmbH...