Technical Data
ES430.1 - User’s Guide
81
8.1.3
Environmental Conditions
8.1.4
Maintenance the Product
Do not open or change the module! Works on the module housing may be exe
-
cuted only by qualified technical personnel. Send defect modules to ETAS.
8.1.5
Cleaning the Product
We recommend to clean the product with a dry cloth.
EN 61000-4-2
Interference immunity: ESD
EN 61000-4-3
Interference immunity: spurious irradia
-
tion
EN 61000-4-4: 2005
Interference immunity: burst
1)
Power supply: 2 kV (peak), 5/50 ns tr/th,
5 kHz repetition rate; I/O cables: 1 kV
(peak), 5/50 ns tr/th, 5 kHz repetition
rate
EN 61000-4-5: 2007
Interference immunity: surge
1)
1 kV symmetrical, 1.2/50 (8/20)
s tr/th
EN 61000-4-6
Conducted disturbances immunity
DIN EN 55022 B
Emission: irradiation/radiated interfer
-
ing voltage, class B
1)
1)
: The module must be powered by a direct current power supply or a battery
with operation voltage. Between module and power supply unit cables with a
maximal length of 30 m are permitted.
Operating temperature range
Operating voltage 5 V to 50 V DC:
-40 °C to +85 °C/ -40 °F to +185 °F
Operating voltage 6 V to 50 V DC:
-40 °C to +120 °C/ -40 °F to +248 °F
Storage temperature range
(module without packaging)
-40 °C to +125 °C
-40 °F to +257 °F
Implementation altitude
max. 5000 m/ 16400 ft
Protection class
IP67
CAUTION
Loss of features as defined by IP67!
Do not open or change the module!
Work on the module must only be carried out by specialist, qualified person
-
nel.
Norm
Test