OPERATING INSTRUCTIONS
MD 180i/16 BASIC
MD 180i/16 BASIC CH
17 / 19
GB
7
Technical data
Operating voltage
230 V
~
µ = contact opening width
≤ 1.2 mm
Target brightness value approx.
5 - 1000 lux
Switching capacity
2300 W / 10 A (cos phi = 1)
1150 VA / 5A (cos phi = 0.5)
Max. inrush current
800 A / 200 µs
Switch-off delay time
Short pulse / approx. 9 sec. - 30 min.
Protection type / protection class
IP 40 / II
Operating temperature range
0 °C to +50 °C
CE according to the following guidelines
EMC standard
2004/108/EC
LVD standard
2006/95/EC