OPERATING INSTRUCTIONS
MD 180i/16 BASIC
MD 180i/16 BASIC CH
7 / 19
GB
5 Activation
Connect the power supply.
A warm-up phase of 25 seconds is initiated. The
red LED (for C1) and the blue LED
flash alternately: 2 x red and 1 x blue. During this time, the lighting is switched on.
5.1
Overview of factory settings
Factory settings
Light value
approx. 100 lux
Switch-off delay time 5 min.
Sensitivity
100 %
6 Settings
6.1
Control via external “S” button
The wall-mounted motion detector is equipped with a connection for an external
button (S terminal). This can be used to switch the lighting on and off manually.
Modes activated by pressing the external button:
Press button for approx. 1 second: The lighting is switched on or off.
Acknowledgement: green LED
Press button for approx. 3 second: The lighting is switched on or off continuously for
4 hours
Acknowledgement: red LED
Press button for approx. 5 second: The lighting is switched on or off continuously for
12 hours
Acknowledgement: blue LED