INSTALLATION 31
Note: the GSM signal strength can also be checked by means of the
associated LED placed on GSM200 module.
¾
Connect the battery (2Ah 12V), paying attention to terminal polarity. In
case of error the battery protection fuse is interrupted.
¾
Disconnect the device from the mains to check the battery operation and
reconnect the device to the mains.
Q
UICK INSTRUCTIONS TO CHECK THE CORRECT
INSTALLATION
1.
PROGRAMMING
•
Program the telephone line (PSTN or GSM, by means of the
proprietary GSM200 module): dial
from the local
telephone. You will hear 3 short tones. Dial
for PSTN line
or
for GSM line.
•
Program a telephone number for the emergency call: lift the handset
of the local telephone and dial:
<telephone
number>
.
•
Record the identification message: (max 22 seconds), which must
contain information about the elevator’s location: dial
and
record the message.
•
To listen to the message again : dial
.
•
Make an outgoing call in order to check the telephone line: lift the
handset of the local telephone , press
and dial a telephone number.
2. CHECKING THE ALARM PROCEDURE
Press emergency button 1 for more than 2 seconds (factory default setting). The
alarm must start.
Содержание Helpy L300
Страница 1: ...Elevator alarm system USER S MANUAL Installation and use...
Страница 18: ...18 OPERATION...
Страница 22: ...22 OPERATION Press the Acknowledge code by default to listen to the message again...
Страница 27: ...INSTALLATION 27 Other connections...
Страница 50: ...50 PROGRAMMING handsfree connection upon alarm 2 minutes Installer password 0 Operator password 0...
Страница 86: ...Helpy L300 25 03 2008...