26 INSTALLATION
•
Make sure that Jumpers JP11 e JP12 are set as in position 1-2 (default
setting).
•
Connect the telephone line to terminal LTI.
GSM200 Module Connection:
•
Please see also the GSM200 User Manual.
•
Make sure that Jumpers JP11 e JP12 are set as in position 2-3 (towards
the RJ45 connector)
•
Connect the cable supplied with the GSM module to connector RJ45 (D in
the figure 24).
Note: when connecting the GSM200 Module, please make sure that
a 2A/h-12V battery is connected with Helpy L300.