OPERATION 11
OPERATION
O
PERATION IN IDLE STATE
In idle state the device (if these checks are enabled):
•
Checks the battery status every 2 hours (“dead battery” technological
alarm);
•
Checks the operation of the alarm system (diagnostics) every day at
programmable time.
If the one of these checks shows a malfunction (dead battery or malfunction
detected by the diagnostics procedure) the device starts the alarm procedure
described in “Alarm calls”.
•
Makes a periodical automatic test call in compliance with EN 81-28:2004
with programmable frequency.
At the time set for the periodic automatic test call the device will call the
programmed number (or numbers) according to the procedure illustrated in
section “Automatic Test calls ”.
A
LARM CALLS
WARNING
If the alarm procedure is activated by mistake and
you have programmed a wrong number, and IT IS
IMPOSSIBLE TO INTERRUPT THE ALARM
PROCEDURE REMOTELY, please follow the
procedure below: lift the handset of the local
telephone and enter * <Key word> # within 20
seconds (by default:
)
. The alarm ends
and the device returns to the idle state.