Card displays show “---“ “---
“
▪
Emergency button pressed
Re-set the emergency button in turning it
in counter-clockwise direction
One or more keys of the
membrane control panel do
not operate
▪
General damage of the membrane control
panel :
▪
a key
▪
a rail
▪
a flat cable
Replace the membrane control panel.
Card displays show ERR
008
Water missing
Check water supply network and if
water taps are open. Check if the
counterlitre operates well (select
program “W”, then press the key (13): on
the display (5) the central line has to
move from the left to the right. Check the
eletrovalves.
After setting of the cycle
time, distribution etc, by
pressing the key
PROGRAMM to store the
program, the card display
shows ERR 009 or ERR
010
Wrong programming of distribution time.
ERR 009 is displayed indistribution mode
r “ delay” _d1 only
ERR010 is displayed in distribution mode
r “delay” _d2 only
Check the mixture time and ingredient
distribution time; this latter has to be
lower than the total cycle time (sum of
1
st
and 2
nd
speed time). If the
distribution time is wrong, it is not
possible to go out from the
programming; to do that, change the
distribution time.
During the execution of
mixture cycle, by pressing
keys 4 or 7, the display
shows ERR 009 or ERR
010
The cycle time has ben reduced to achieve
the distribution initial time of dispenser 1
(ERR 009) or dispenser 2 (ERR 010) and in
r “delay” mode
If the mixture cycle has to be reduced,
change the distribution time in the
program. If distribution has started, this
runs on even if the work cycle shall be
suspended or terminated.
Temperature display shows
000
Probe has a fault
Temperature probe in short circuit
Temperature display shows
99.9
Probe has a fault
Temperature probe interrupted or
disconnected
SPI 30 - 45 - 60 - 80 - 100 - 130 - 160 - 200, M Version
Failure/Anomaly
Possible Cause
Possible Remedy
Main power switch in
position (ON – I), the leds
of the timers (2) and (5) do
not switch on
Transformer fuses
Trasformer
Timer
Open the electrical box and check the
fuses of FU1-FU2 transformer.
Check the presence of tension in the
transformer secondary.
Check the funtion of timers.
By pressing the key start
(15) the machine does not
start
Elergency button pressed
Start button defective
Bowl cover microswitch
Release the emergency button (turn it
clockwise ).
Check and, if needed, replace the
defective parts.