20
Kongsberg X-series
Pressing the Fault Reset button will cause the safety circuit to be reset, providing there are no active
machine faults.
The blue light will stop flashing when the i-BF safety circuit is reset.
6 - Bumper Bypass pushbutton
There may be occasions where a safety bumper is pressed and cannot be released due to a mechanical
jam.
The safety system cannot be reset when a safety bumper is pressed.
The Safety Bumper Bypass pushbutton located on the left side of the
control panel, allows the safety bumper system to be bypassed to allow the i-
BF to be jogged out of the mechanical jam situation.
Note: The bypass feature is only operational while a safety bumper is
pressed and the mode selector switch is set to Manual.
You need to first enable jogging for the jammed axis on the touch screen.
You need to hold in the Bumper Bypass pushbutton while jogging.
This bypass allows the operator to reset the safety circuit and jog the i-BF out of the jammed condition.
Note
: Jogging during bumper bypass is for safety reason limited to a low speed, 1 m/min / 0.66 ips.
The Safety Bumper Bypass Pushbutton is located on the side of the pedestal.
20.9. Feeder Sequence of Operation
A - Home Feeder
The feeder must be homed after switching on the power.
Homing consists of:
1. The carriage beam moves to its home position, which is in the full upwards beam position,
221