22.
Command list / command set
Commands can be sent directly via a terminal program or the Config-Tool 3. With the "SEND" button the entered
command is sent to the 1-Wire Controller / 1-Wire Gateway. Blank lines should not be inserted. The separator
between the command parts is a comma. Upper and lower case do not need to be considered, too. All data
output is in capital letters.
Example: Query time (get,sys,time)
22.1.
SET Command
Commands to change settings or to execute an activity (SET). The subcommand is divided into System (SYS),
One Wire Bus (OWB) and One Wire Device (OWD).
22.2.
System Set Command (System Command)
1
2
3
4
5
Description
SET
SYS
RST
1
Reset of the 1-Wire Controller / 1-Wire
Gateway with restart
DATE
Setting the date in the 1-Wire Controller /
1-Wire Gateway
Input format: day,month,year => 04.12.14
TIME
Setting the time in the 1-Wire Controller /
1-Wire Gateway
Input format: hour:minutes:seconds
DEBUG
0-2
Output test output on/off, default: 0
RUN
0 or 1
Activate/deactivate data output and querying of
the 1-Wire blocks.
0=off (Stop), 1= Data output (Run)
ECHO
0-2
0=Confirmation with "0" (=ok), of the
corresponding data record or an error
message,
1=Output of the result with data frame
2=Output of the command as pure echo
default setting:1
LOADDEFAULT
1
Loads factory settings.
The previous settings are overwritten.
The 1-Wire List (OWD List) is not deleted.
SAVE
Saves the current settings in the S-RAM
1
LOAD
1
Loads the last saved 1-Wire Controller / 1-Wire
Gateway settings from the S-RAM
CONTNO
1-254
Sets a 1-Wire Controller /
1-Wire Gateway number, Default=1
FACRESET
1
The device is set to the factory setting.
1
Static memory that retains even after the operating voltage has been switched off.