B
A
C
D
E
F
G
SER
VICE
53
S4 Cleaning the Fascia
NEVER RUB THE FASCIA. The outside of the fascia’s must only be cleaned with a clean damp cloth,
dry off after cleaning. The high temp silver powder coating that is used on Escea fascia parts contains
certain amounts of aluminium that when rubbed too hard will oxidise leaving a black smudge that
cannot be removed. For stainless steel fascias:
we recommend the use of Steel Kleen brand Ezi Wipes.
Always clean when cold.
S5 Cleaning the Log Set and Glass
This is a service procedure that will need to be carried out whenever soot builds up on logs and/or
inside of glass. If soot build up becomes excessive or regular then one of the following actions may be
required:
•
Check gas pressure; operating gas pressure may be too high.
•
Reposition log set so that each log is sitting correctly in the log retainer bracket.
•
Clear any blockage from primary air port of burner.
•
Check flue tube is not damaged or disconnected.
For diagrams and further info on removing your fascia, reverse the steps found in section F.
•
Refer to section D2 for instructions on removing the glass.
•
Clean the inside and outside of both pieces of glass with normal glass cleaning products.
Use a CLEAN DRY cloth only. Stubborn marks may be cleaned with a ceramic glass
cleaner.
•
Replace in opposite order and test run heater.
S6 Removing or Cleaning Fan
As part of regular service procedure, it is recommended that the fan is removed for cleaning. Dust will
build up on the fan rotor and in the cavity where the fan is located. This can be removed by the service
person using a hearth brush and a vacuum cleaner.
ISOLATE THE POWER AND GAS SUPPLY TO THE FIRE BEFORE COMMENCING THIS
PROCEEDURE.
Remove the electronic tray located on the base of the chassis (instructions provided in the next sec-
tion ) before attempting to remove the room air fan. Disconnect the 3-way fan connector and remove
the two screws circled in the diagram below (the AF960 requires the LH access hatch to be removed
in order to get to the LH screw) . The room air fan can now be pull towards you and removed through
the burner tray hole.
AF700 Fan Screw Locations
Содержание AF series
Страница 3: ......
Страница 47: ...B A C D E F G SERVICE 47 G4 Gas pipe Routing Information ...
Страница 58: ...B A C D E F G SERVICE 58 S11 Wiring Diagram ...