G6 Inroom Horizontal Flue Kit
For horizontal termination the following are dimensions for installing the Inroom Horizontal flue kit.
Note: Instructions for installation are provided with the kit
G7 AF700 Fireplace installation into FS730 Freestanding Unit
Once the freestanding unit is in place, and the flue system installed, the AF700
fireplace installation can commence.
Note:
for the Apartment Flue Kit, see the instructions provided with the kit.
Place the freestanding unit in the correct location, complying with the
clearances specified in the previous section.
Remove 2 screws on each side of the fascia just below the top panel and pull
towards you to remove the fascia.
Refer to section C of this installation manual for minimum and maximum flue
lengths, restrictor settings for your installation, and all other flue information.
Prepare the flue for fire installation, by sliding the flexible flues down the liner
and attaching to the flue spigot plate as per the end of section C
Take the plastic grommet in the back panel out. Push the power cable through
the hole in the rear, then push the grommet over the power cable and fix the
grommet back to the back panel.
Install the AF700 fireplace into the freestanding unit while sliding on the flue
spigot plate as per section E.
Run gas piping to the front right of the fireplace as shown, where you will find
a hole positioned so the gas pipe can run directly to the regulator and be connect-
ed as per section E.