C14 Connecting the Flexi flue to the Masonry Terminal Kit (46DVA-CL34)
NOTE: The chimney kit 46DVA-CL34 must only be installed into a non-combustible masonry or
concrete chimney.
Locate the 100mm (4”) exhaust flexi flue. Stretch the flexi flue to the desired length ensuring that
the end part that fits onto the exhaust spigot is completely extended (stretched).
Locate the 100mm (4”) exhaust flue onto the exhaust spigot.
Locate 1 X 100mm diameter stainless steel band clamp provided with the 46DVA-CL34 flexi flue
kit. Mark, centre punch and drill 3 x 4.0mm diameter holes approximately equally spaced around the
diameter of the band clamp. Place the band clamp over the exhaust flexi flue and tighten.
ONLY TIGHTEN ENOUGH TO JUST HOLD AND PREVENT THE FLEXI FLUE FROM
COMING OFF THE SPIGOT IF PULLED ON. OVER TIGHTENING THE CLAMP WILL CRUSH
& DAMAGE THE FLEXI FLUE.
Screw a self-tapping screw (provided with the 46DVA-CL34 flexi flue kit into each of the 3 holes
through the band clamp and into and through both the flexi flue and exhaust spigot.
Ensure that the joint is sound and secure.
The joint on the 75mm intake spigot is achieved in
the
same manner.