AF960
PRODUCT SPECIFICATION
MODEL NAME
AF960
Description of Appliance
Gas Fire Heater
Star Rating
3.5-3.75 Stars
A/NZ Approval No.
AS 4553
Gas Type
Natural
Propane
ULPG
Gas input
High
31 MJ/hr
31 MJ/hr
28 MJ/hr
Low
15 MJ/hr
14 MJ/hr
12 MJ/hr
Inlet Pressure
Max
5.0 kPa
5.0 kPa
5.0 kPa
Min
1.13 kPa
2.75 kPa
2.75 kPa
Operating Pressure on High
1.0 kPa
2.30 kPa
2.30 kPa
Operating Pressure @ Front Burner Jet on High
0.94 kPa
2.20 kPa
2.20kPa
Burner Jet Size
Front: 1.90mm
Rear: 1.70mm
Front: 1.20mm
Rear: 1.05mm
Front: 1.10mm
Rear: 1.02mm
Aeration Collar hole size for Logs & Flakes
2 holes @ Ø6mm
No Collars
No Collars
Aeration Collar hole size for Coals
1 hole @ Ø3.5mm 2 holes @ Ø7mm
2 holes @ Ø10mm
Pilot injector
#42
#27
#27
Appliance Dimensions (mm)
Width
943.0 mm
Height
596.0 mm
Depth
402.0 mm
Weight
Kg
70 kg
Ignition System
Electronic Ignition to pilot system
Escea PCB
Ignition Activation
7 secs (approx)
Flame Safeguard
Flame Rectification
Consumption
84W @ 0.35A 230V
Remote controls
Yes
Timers
Yes
Clock
Yes
Function lock / child
Yes
Temperature control
Yes
Connections
Electric 230V AC
Gas 1/2" BSPP female lower right of fireplace chassis
Flue Type
Simpson Duravent Direct Vent (False Chimney)
Flexi Flue (Masonry)
Flue Size
6" mm Outer, 4" mm Inner (Direct Vent)
4" and 3" Flexi Flue (Masonry)
Spigot
Location
Rear and centre
Data badge location
On Chassis Base