52
Appliance Over
Temperature
Sensor Trip
The bimetallic snap disk mounted on the back chassis panel has tripped. The
possible causes for this could include:
•
Fascia may be installed incorrectly resulting in restricted air flow.
•
The room air fan may be slowed or stalled. Remove firebox, check that
the fan is plugged in, cleaned, and free turning.
•
The gas regulator being set too high resulting in excess heat build-up.
•
The inlet flue not being connected and the appliance drawing warm air
from the cavity. Check flues are securely connected at both ends.
Valve Solenoid
Check Failure
The valve solenoids have failed the pre-ignition test. This is to detect a faulty
valve solenoid. However, it is possible a wire has dislodged.
•
Check that the connections to each solenoid are secure and in place. It
may be that the connections on the ends of the wires need to be tight-
ened a little (e.g. with a pair of pliers) to ensure a robust connection to
the valve terminal.
•
Disconnect and reconnect the firebox connectors ensuring they are
firmly pushed into place.
•
It could also be that one of the solenoids on the valve inside the fire has
failed. If this is the case the valve will need to be replaced.
Internal Remote
Error
Internal remote error:
•
Press the on/off button on the remote to clear the error.
S2 Serial
Number
The serial number for the fire can be found in two places. The first is in the battery compartment of
the wireless remote under the batteries. The second is on the data sticker on the chassis under the
firebox on the left hand side.
S3 Checking Operating Pressure
See section E9 of this manual.