Masonry Installation Requirements
The masonry install requires a spacer below the appliance to allow room for the fascia to sit flush with
the ground.
B2 Floor
Clearances
If the appliance is mounted above a “hard floor” (including but not necessarily limited to: wood, wood
veneers, ceramic tiles, concrete and stone) then it may be positioned with the bottom of the fascia
coincident with the finished floor if desired. Note: The appliance has been tested and certified to
AS4553:2008 and the maximum allowable temperature rise above ambient of any combustible floor
is ΔT of 65C. Therefore any material used must be chosen to be able to operate without damage or
degradation with a ΔT of 65C.
If the appliance is mounted above a “Soft floor” ” (including but not necessarily limited to: carpets,
Vinyl, carpet tiles, rugs and mats) then we recommend a distance of 100mm from the bottom of the
fascia to the finished floor.
Refer to section B4 for hearths.
B3 Flexi Flue & Converter Box Clearances
25mm
=
Minimum distance to combustibles
50mm
50mm
0mm*
*
Note: Underside of converter box can be fixed straight onto wooden joists.
**
Note: Flexi-Flue must not be run at an angle greater than 45 degrees from
vertical; excluding all appliance built into a freestander kit.
50mm
50mm
>45°**
50mm
Ø75mm I
ntake
Ø100mm Exhaust
50mm
25mm
25mm
600mm
300mm t