F
Fitting the Fascia and Finishing Installation
F1
Fitting the Fascia
Slide the top of the fascia (the side with two prongs facing away from the front face) into the fascia
rails attached to the chassis in the two top corners. Push the bottom fascia lip above the chassis base.
The fascia should now be flush with the wall.
F2 Locating Wall Mount Cradle for Wireless Control
The appliance’s remote contains the thermostat that will sense the room temperature and communi-
cate this back to the heater via radio frequency.
A wall mount cradle has been provided for the wireless control and where possible the control should
be housed in this cradle.
The location of this cradle should be decided by taking into account the following factors;
Simple, convenient access for the user
Away from air flow and drafts through the room
The parts of the room that people are likely to spend time
Away from direct sun light
A suitable distance away from the heater.
Ideally 1.2m to 1.5m from the floor
The radio frequency signal will go through some walls but for best results Escea suggest that the cradle
position is between 1 and 5 metres away from the heater.
Please ensure that cradle is screwed firmly onto the wall using the screws provided.