Fault message
Possible causes
Suggested corrective measures
CAN’T MAKE SHARP
1. Monitor out of focus.
1. Adjust the focus.
2. Internal splicer error.
2. Service the splicer.
BAD VIEW ANGLE
1. The V-grooves are dirty.
1. Clean the V-grooves.
2. The V-grooves are out of alignment. 2. Service the splicer.
INTERNAL ERROR
Splicer needs service.
Service the splicer.
CANNOT ESTIMATE LOSS
1. Bad splice picture.
1. Re-fuse the fibers.
2. Wrong parameters used in
2. Check the program and program
program.
parameters, and then re-splice.
3. If it happens very frequently, it
3. Service the splicer.
means the optical system is faulty.
BAD SPLICE
Unsuccessful splice.
Re-splice the fibers.
XCT OUTSIDE RANGE
1. Bad conditions of electrodes
1. Clean electrodes (see p.68)
2. Light emissions from right and
2. Try splicing other fibres to see if
left fibre differ too much
problem persists
3. Splicer needs service
3. Service the splicer
General fault messages (cont.)
Fault message
Possible causes
Suggested corrective measures
SELECT # NOT PRESSED
During the threshold type test, the
Redo threshold type test.
COMPUTE THRESHOLD?
#-button was not pressed, and thus
no new loss data was saved.
NO THRESHOLD FOUND
Insufficient data for calculating
Re-do the test, paying special attention to
DO SELECT NEXT TIME
a threshold type.
taking data for splice loss measurement.
NO THRESHOLD FOUND
Insufficient data for calculating
Reduce FUSION TIME 2 and re-do test.
TRY REDUCE TIME 2
a threshold type.
NO THRESHOLD FOUND
Insufficient data for calculating
Increase FUSION CURRENT 2 and re-do
TRY INCREASE CURR. 2
a threshold type.
test.
NO THRESHOLD FOUND
Insufficient data for calculating
Reduce FUSION CURRENT 2 and re-do
TRY REDUCE CURR. 2
a threshold type.
test.
NO THRESHOLD FOUND
Insufficient differences in index
Try splicing with the normal splicing
TRY NORMAL PROCESS
profiles to calculate a threshold
process.
type.
Mode field matching fault messages
When you have gotten a fault message and made note of
what you should do, you can then return to the on-going
procedure by pressing the ESC button.
k
Содержание FSU 995 F
Страница 1: ...Established 1981 Advanced Test Equipment Rentals www atecorp com 800 404 ATEC 2832...
Страница 2: ...FSU 995 FA User s manual 133ST010R1A...
Страница 3: ...1 User s manual for the FSU 995 FA single fiber fusion splicer by Ericsson...
Страница 4: ...2...
Страница 26: ...24...
Страница 85: ...83...