40
Parameter
Function
Range
Default
ADVANCED OPERATION - Splicing program structure: Parameters
The splicing parameters listed on this page will be discussed in greater detail in the section on “Advanced
splicing parameters,” p. 55.
LEFT MFD
Mode field diameter
2.0 to 19.9
m
m
9.8
m
m
for left fiber
RIGHT MFD
Mode field diameter
2.0 to 19.9
m
m
9.8
m
m
for right fiber
SET CENTER
Sets normal splicing or
150 to
255 pixels
off-center splicing
360 pixels
AOA CURRENT
Arc-on-alignment current
6.0 to 29.9 mA
0
Disable by setting to 0.
EARLY PREFUSION
Do prefusion before any
YES/NO
NO
alignment
ALIGN ACCURACY
Accuracy for axis alignment
0.01 to 9.99
m
m
0.15
m
m
LOSS SHIFT
Adjusts the difference
-1.00 to +1.00
0 db
between estimated and
measured loss
AUTO ARC CENTER
Activate the
Automatic Arc
YES/NO
NO
Re-centering
function