18
At this point you should have chosen Manual mode for the
splicing mode (see p.14), and a splicing program. To continue
our example, we will assume you have chosen Program 03
for titanium fiber splicing. This will give you the adjacent
screen, with “FSU 995 FA MANUAL MODE” in the
mode field
and the program name (“TITAN SM + SM”) and program
number (P03) in the
message field
.
The splicer will then display a series of messages in the
message field
that tell you that it is ready.
READY FOR PREFUSING
PRESS FUSE BUTTON
“
“
Splicer ready
1
Roughly align fibers
2
In order to roughly align the fibers with respect to each other,
you should alternately press the and buttons for both
the right and left fibers until the outer edges of the fibers line
up.
When you think the fibers are lined up, you can start bringing
the fibers towards each other by alternatively pressing the
and buttons for each of the fibers. Your goal is a gap
equivalent to half a diameter of a fiber, centered horizontally
in the monitor (see illustration below).
You should then press the VIEW button to ensure that the
gap is also correct from the other camera angle.
+
After rough alignment the situation should be as follows:
the outer edges of the fibers line up, and the gap between
their end-faces is the width of half a fiber diameter, and
centered on the monitor.
Outer diameter alignment
+
Gap alignment
View
Check gap in other view
Gap
centered
Gap width of half
a fiber diameter
Outer edges lined up
Manual mode splicing
FSU 995 FA MANUAL MODE
TITAN SM + SM P03
BASIC OPERATION - Manual mode splicing