![Ericsson ECN330 Скачать руководство пользователя страница 602](http://html1.mh-extra.com/html/ericsson/ecn330/ecn330_user-manual_2423382602.webp)
Command Line Interface
596
1553-KDU 137 365 Uen D 2006-06-16
7.5.41
logging sendmail level
This command sets the severity threshold used to trigger alert messages.
Syntax
logging sendmail level <
level
>
level
- One of the system message levels (page 585). Messages sent
include the selected level down to level 0. (Range: 0-7; Default: 7)
Default Setting
Level 7
Command Mode
Global Configuration
Command Usage
The specified level indicates an event threshold. All events at this level or
higher will be sent to the configured email recipients. (For example, using
Level 7 will report all events from level 7 to level 0.)
Example
This example will send email alerts for system errors from level 3 through 0.
Console(config)#logging sendmail level 3
Console(config)#
Содержание ECN330
Страница 6: ...1553 KDU 137 365 Uen D 2006 06 16 Contents List of Abbreviations 1183 Glossary 1191 Index 1201...
Страница 22: ...Introduction to the ECN330 switch 16 1553 KDU 137 365 Uen D 2006 06 16...
Страница 26: ...Maintenance 20 1553 KDU 137 365 Uen D 2006 06 16...
Страница 56: ...Initial Configuration 50 1553 KDU 137 365 Uen D 2006 06 16...
Страница 520: ...Configuring the ECN330 switch 514 1553 KDU 137 365 Uen D 2006 06 16...
Страница 1188: ...Specifications 1182 1553 KDU 137 365 Uen D 2006 06 16...
Страница 1196: ...List of Abbreviations 1190 1553 KDU 137 365 Uen D 2006 06 16...
Страница 1224: ...Index 1218 1553 KDU 137 365 Uen D 2006 06 16...
Страница 1225: ......
Страница 1226: ...Created by EBCCW 00 06 Ericsson AB 2006 All Rights Reserved 1553 KDU 137 365 Uen D 2006 06 16 Ericsson AB www ericsson com...