3.6 Connecting the Cables
WARNING
■
To shut off power to the robot system, disconnect the power plug from the power
source. Be sure to connect the AC power cable to a power receptacle.
DO NOT connect it directly to a factory power source.
■
Before performing any replacement procedure, turn OFF the Controller and
related equipment, and then disconnect the power plug from the power source.
Performing any replacement procedure with the power ON is extremely
hazardous and may result in electric shock and/or malfunction of the robot
system.
■
Be sure to connect the cables properly. Do not allow unnecessary strain on the
cables. (Do not put heavy objects on the cables. Do not bend or pull the
cables forcibly.) The unnecessary strain on the cables may result in damage to
the cables, disconnection, and/or contact failure.
Damaged cables, disconnection, or contact failure is extremely hazardous and
may result in electric shock and/or improper function of the robot system.
■
Grounding the manipulator is done by connecting with the controller. Ensure
that the controller is grounded and the cables are correctly connected. If the
ground wire is improperly connected to ground, it may result in the fire or electric
shock.
CAUTION
■
When connecting the Manipulator to the Controller, make sure that the serial
numbers on each equipment match. Improper connection between the
Manipulator and Controller may not only cause improper function of the robot
system but also serious safety problems. The connection method varies with
the Controller used. For details on the connection, refer to the
Controller
manual
.
If the G series Manipulator is connected to the Controller for the 6-axis robot, it
may result in malfunction of the Manipulator.
When the Manipulator is a Cleanroom-model, be aware of the followings.
When the Manipulator is a Cleanroom-model, use it with an exhaust system.
For details, refer to
Setup & Operation: 2.4 Specifications.
When the Manipulator is a Protected-model, be aware of the followings.
WARNING
■
Connect the power cable connection and the signal cable connector to the
Manipulator immediately after the Manipulator installation. The Manipulator
without connecting them may result in electric shock and/or malfunction of the
robot system as it cannot ensure IP54 / IP65.
CAUTION
■
When operating the Manipulator under special environmental conditions (adverse
conditions with dust and oily smoke), do not place the controller in the same
condition since the controller does not comply with IP54 / IP65. Doing so may
cause equipment damage to and/or malfunction of the controller.
Содержание G6 series
Страница 1: ...Rev 21 EM183R3621F SCARA ROBOT G6 series MANIPULATOR MANUAL ...
Страница 2: ...MANIPULATOR MANUAL G6 series Rev 21 ...
Страница 8: ...vi G6 Rev 21 ...
Страница 14: ......
Страница 93: ...Maintenance This volume contains maintenance procedures with safety precautions for G6 series Manipulators ...
Страница 94: ......
Страница 120: ...Maintenance 4 Cable 108 G6 Rev 21 Table Top mounting Cable Unit Wall mounting Cable Unit Ceiling mounting Cable Unit ...
Страница 135: ...Maintenance 4 Cable G6 Rev 21 123 Table Top mounting M C Cable Wall mounting M C Cable Ceiling mounting M C Cable ...
Страница 216: ...Maintenance 14 Maintenance Parts List 204 G6 Rev 21 ...