Maintenance 4. Cable
112
G6 Rev.21
(18) Disconnect the Base side cables from Arm #1.
Table Top mounting
: Disconnect from the upper part of Arm #1
Wall mounting, Ceiling mounting
: Disconnect from the lower part of Arm #1
When disconnecting the cables, first, disconnect
the air tubes. Then, disconnect from the
smaller connectors in order.
Do not try to disconnect the cables forcibly.
Otherwise, connectors may be stuck,
disconnected, or connector pins may fall off.
Cable
Table Top mounting
Cable
Wall / Ceiling mounting
(19) Disconnect the cables that were disconnected
from Arm #1 in step (18) to the side of Arm #1.
Cable
Table Top mounting
Cable
Wall / Ceiling mounting
(20) Disconnect the Arm #2 side cables from the
lower part of Arm #1.
When disconnecting the cables, first, disconnect
the air tubes. Then, disconnect from the
smaller connectors in order.
Do not try to disconnect the cables forcibly.
Otherwise, connectors may be stuck,
disconnected, or connector pins may fall off.
Cable
(21) Disconnect the cables that were disconnected to
the lower part of Arm #1 in step (20) to the side
of Arm #1.
Cable
(22) Remove the Arm #1 four mounting bolts on the
spring plate side.
4-M6
×
15
(23) Disconnect the cables to the base side.
NOTE
NOTE
Содержание G6 series
Страница 1: ...Rev 21 EM183R3621F SCARA ROBOT G6 series MANIPULATOR MANUAL ...
Страница 2: ...MANIPULATOR MANUAL G6 series Rev 21 ...
Страница 8: ...vi G6 Rev 21 ...
Страница 14: ......
Страница 93: ...Maintenance This volume contains maintenance procedures with safety precautions for G6 series Manipulators ...
Страница 94: ......
Страница 120: ...Maintenance 4 Cable 108 G6 Rev 21 Table Top mounting Cable Unit Wall mounting Cable Unit Ceiling mounting Cable Unit ...
Страница 135: ...Maintenance 4 Cable G6 Rev 21 123 Table Top mounting M C Cable Wall mounting M C Cable Ceiling mounting M C Cable ...
Страница 216: ...Maintenance 14 Maintenance Parts List 204 G6 Rev 21 ...