Maintenance 11. Lithium Battery
G6 Rev.21
179
11.1 Replacing the Battery Unit (Lithium Battery)
Battery unit
(lithium battery)
Removal
(1) Turn OFF the Controller.
(2) Push down the shaft to its lower limit while pressing the brake release switch. Be
sure to keep enough space and prevent the end effector hitting any peripheral
equipment.
The brake release switch is applied to both Joints #3 and #4. When the brake
release switch is pressed, the respective brakes of the Joints #3 and #4 are released
simultaneously. (The brake for Joint #4 is only installed to G6-**3**.)
Be careful of the shaft falling and rotating while the brake release switch is being
pressed because the shaft may be lowered by the weight of an end effector.
(3) Remove the arm top cover.
For details, refer to
Maintenance: 3.1 Arm Top Cover
.
(4) Connect the connector of the new lithium battery to
the battery board.
User the unused connector of the two connectors
X60A, X60B on the upper part of the battery board.
Be sure to connect the connector of the new battery
before disconnecting the old battery. If the current
battery is disconnected before connecting the new
one, the robot will lose the origin position data and
the calibration must be executed again.
Except when the Power-Low warning is appearing.
X60A
Battery board
X60B
Wire tie
(5) Cut off the wire tie banding the lithium battery and
remove the lithium battery.
Lithium battery
Battery board
(6) Cut off the wire tie banding the lithium battery,
Remove the battery.
Battery unit
(lithium battery)
Installation
(1) Mount the new lithium battery to the battery board.
(2 ) Fix the cable of lithium battery and connector cable connecting to battery board with
wire tie. Refer to the procedure (4).
(3) Mount the arm top cover.
For details, refer to
Maintenance: 3.1 Arm Top Cover
.
(4) Turn ON the Controller.
(5) Check if the Manipulator moves to points (poses) correctly.
To do so, select 2 points (poses) or more from the registered points (poses) and move
the Manipulator to the points (poses).
(6) If the Manipulator does not move to the points (poses) correctly, perform the
calibration of all joints and axes.
For details, refer to
Maintenance: 13. Calibration
.
NOTE
Содержание G6 series
Страница 1: ...Rev 21 EM183R3621F SCARA ROBOT G6 series MANIPULATOR MANUAL ...
Страница 2: ...MANIPULATOR MANUAL G6 series Rev 21 ...
Страница 8: ...vi G6 Rev 21 ...
Страница 14: ......
Страница 93: ...Maintenance This volume contains maintenance procedures with safety precautions for G6 series Manipulators ...
Страница 94: ......
Страница 120: ...Maintenance 4 Cable 108 G6 Rev 21 Table Top mounting Cable Unit Wall mounting Cable Unit Ceiling mounting Cable Unit ...
Страница 135: ...Maintenance 4 Cable G6 Rev 21 123 Table Top mounting M C Cable Wall mounting M C Cable Ceiling mounting M C Cable ...
Страница 216: ...Maintenance 14 Maintenance Parts List 204 G6 Rev 21 ...