© EPS Stromversorgung in 2022, this information is subject to change without notice
53
30000800_manual_psb_10000_4u_30kw_en_04
Settings for the internal Ethernet port
IF Settings
Description
Et
he
rne
t (
in
te
rnal
)
DHCP
The IF allows a DHCP server to allocate an IP address, a subnet mask and a gateway. If no DHCP
server is in the network then network parameters will be set as defined below.
IP address
Manually allocate an IP address.
Subnet mask
Manually allocate a subnet mask.
Gateway
Manually allocate a gateway address, if required.
DNS address
Manually allocate addresses of a Domain Name Server (DNS), if required.
Port
Select port in the range 0...65535. Default:
5025
Reserved ports: 502, 537
Host name
User definable host name
Domain
User definable domain
MAC address
of the internal Ethernet port
Settings for the optional interface modules (IF-AB-xxx)
IF Settings
Description
CA
N
op
en
Baud Rate
CAN bus baud rate selection that is used by the CANopen interface.
Auto
= Automatic detection
LSS
= Baud rate and node address are assigned by the bus master
Fixed baud rates:
10 kbps
,
20 kbps
,
50 kbps
,
100 kbps
,
125 kbps
,
250 kbps
,
500 kbps
,
800 kbps
,
1Mbps
Node Address
Selection of the CANopen node address in the range
1
...
127
IF Settings
Description
Pro
fib
us
Node Address
Selection of the Profibus or node address of the device within range 1...125 via direct input
Function Tag
String input box for a user-definable text which describes the Profibus slave function tag. Max.
length: 32 characters
Location Tag
String input box for a user-definable text which describes the Profibus slave location tag. Max.
length: 22 characters
Installation Date
String input box for a user-definable text which describes the Profibus slave installation date tag.
Max. length: 40 characters
Description
String input box for a user-definable text which describes the Profibus slave.
Max. length: 54 characters
Manufacturer ID
Registered manufacturer ID with the Profibus organization
Ident number
Product identification number, same as in the GSD file
IF Settings
Description
Pr
ofi
ne
t/
IO (
1 & 2 P
or
t)
Host name
Free choice of host name (default:
Client
)
Domain name
Free choice of Domain (default:
Workgroup
)
Function Tag
String input box for a user-definable text which describes the Profinet slave function tag. Max.
length: 32 characters
Location Tag
String input box for a user-definable text which describes the Profinet slave location tag. Max.
length: 22 characters
Installation Date
String input box for a user-definable text which describes the Profibus slave installation date tag.
Max. length: 40 characters
Description
String input box for a user-definable text which describes the Profibus slave. Max. length: 54
characters
Station Name
String input box for a user-definable text which describes the Profinet station name. Max. length:
200 characters