f
ueL
c
onVeRsion
:
TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY
Please read and understand these instructions before installing.
Warning: This conversion kit shall be installed by a qualified service agency in accordance
with the manufacturer’s instructions and all applicable codes and requirements of the
authority having jurisdiction. If the information in these instructions is not followed
exactly, a fire, explosion or production of carbon monoxide may result causing property
damage, personal injury or loss of life. The qualified service agency is responsible for
the proper installation of this kit. The installation is not proper or complete until the
operation of the converted appliance is checked as specified in the manufacturer’s
instructions supplied with the kit.
Kit Parts List for all E33GI models:
1 - Orifice (NG:
#41) or (LP: #54) 1 - Servo Regulator with diaphragm
1 - Installation instruction sheet
2 - Conversion labels
1 - Pilot Orifice (NG: 0.2) or (LP: 0.14)
Carefully inspect all parts supplied with this conversion kit. If any parts have been damaged or are
missing, contact your dealer, distributor or courier company to have them replaced before starting this
installation.
Maintenance And Service
Conversion Kit Installation:
1. Turn the unit off by pressing the ON/OFF Key on the remote and shut off gas supply at the shut-off
valve upstream of the unit. CAUTION: The gas supply must be shut off prior to disconnecting the
electrical power and before proceeding with the conversion. Allow the valve and unit to cool down
to room temperature.
2. Carefully remove the glass media and porcelain tray if they are installed.
3. Remove the burner as shown in the
s
eConDary
I
nstallatIon
- f
Irebox
l
Iner
& b
urner
t
ray
r
emoVal
.
4. Remove the burner as shown in
m
aIntenanCe
anD
s
erVICe
- b
urner
r
emoVal
.
18
Figure 23 Proper Pilot Position
6. Convert the burner orifice:
a) Remove the main burner orifice with a
1/2” deep socket
b) Put a bead of pipe-thread sealant into the orifice mount.
DO NOT OVER-TIGHTEN
c) Install new orifice.
5. Convert the pilot orifice:
a) Using a
7
/
16
” wrench, loosen the pilot head counter
clockwise and fully remove
b) Remove the existing orifice and replace with the one
supplied in the kit (see Figure 22)
c) Re-install the pilot head and tighten until it is back in the
proper position (see Figure 23)
Figure 22 Pilot Orifice