34

TroubleShooting

D

iagnostic

 f

Lash

 c

oDes

 (

Does

 

not

 

appLy

 

to

 e33giD 

moDeLs

):

1. Fail to ignite: If there is no positive ignition, the board will go into lock out and the LED will blink 3 times 

in intervals until the system is reset. 

2. Low battery condition (<4V): the LED indicator will blink one (1) time in intervals. 

3. Parasitic Pilot Flame: the LED indicator will blink two (2) times in intervals. 

4. System Lock out: the LED indicator will blink three (3) times in intervals. 

Additional Ignition Information 

1. The Proflame2 IFC will try two (2) times for ignition. 

2. Each try for ignition will last approximately 60 seconds. 

3. The wait time between the two tries is approximately 35 seconds. 

Figure 54: IFC LED Location

LED Location

35

Содержание E33GI

Страница 1: ... O N e n v i r o c o m w a r r a n t y E33GI E33GID G A S I N S E R T G L A S S B U R N E R w I P I Report 0268GN022S WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Installation and service must be performed by a qualified installer service agency or the gas supplier CERTIFIED TO CERTIFIÉ AUX ...

Страница 2: ...l your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Massachusetts installations Warning This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massac...

Страница 3: ... must be performed by a qualified installer service agency or gas supplier This installation must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 or the Natural Gas and Propane Installation Code CSA B149 1 To prevent injury do not allow anyone who is unfamiliar with the stove to operate it To prevent injury if the pilot or pilot and burne...

Страница 4: ...The Glass 17 Check Pilot and Burner Flames 17 Removing Valve Cover 17 Fuel Conversion 18 Initial Installation 20 Clearances to Combustibles 20 Minimum Fireplace Size 20 Non Combustible Build Out 20 Venting 21 Baffle Plate Adjustment 23 Installing the Unit 24 Zero Clearance Fireplace Installation 26 Electrical Requirements 27 Gas Line Connection 28 Adjusting The Pilot Flame 29 Secondary Installatio...

Страница 5: ...ied for use with either natural or propane gases See rating label Is not for use with solid fuels Is approved for bedroom or bed sitting room IN CANADA must be installed with a permanent wall thermostat for bedroom installations Consult the authority having local jurisdiction in your area IN USA see current ANSI Z223 1 for installation instructions Must be installed in accordance with local codes ...

Страница 6: ...low shows what depth of install is required with each surround panel Table 1 Install Depths Shown with Contemporary surround IPI Valve Figure 1 E33I Exterior Dimensions 27 050 16 644 18 555 29 254 33 000 11 812 9 052 9 085 22 146 19 755 18 249 18 027 21 520 17 576 Surround Panel Required Depth Contemporary 17 445 mm Modern Extruded Extruded Plus 18 457 mm Slim Elite Panels 19 483 mm ...

Страница 7: ...ry Surround Extruded Surround Height 26 5 673 mm 26 5 673 mm 26 5 673 mm Width 44 1 8 1121 mm 44 1 8 1121 mm 44 1 8 1121 mm Trimmable Surround Height Width 38 965mm 46 1168mm Base Shelf Base Shelf Riser Height 1 41 mm 2 54 mm Width 45 1 2 1156 mm 44 1118 mm Depth Bottom 4 112 mm Top 3 13 16 97 mm 3 11 16 94 mm 43 7 8 26 45 1 2 28 3 4 1 2 ...

Страница 8: ...ny part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water OPERATING INSTRUCTIONS 1 STOP Read the safety information above on this label 2 Read the owner s manual including the section on Remote Control operation 3 Turn off all electric power to the appliance 4 Do...

Страница 9: ... in order to accommodate different climates and venting arrangements Start the pilot and then the burner Make sure the pilot flame is burning normally and none of the burner ports are plugged Let the fireplace burn for roughly fifteen 15 minutes and then examine the flames The ideal flame will be blue at the base and light orange above The flames should be of medium height If the flames look like ...

Страница 10: ... A Mode Key is provided to Index between the features and a Thermostat Key is used to turn on off or index through Thermostat functions Figure 5 6 Figure 5 Proflame 2 Transmitter System Description The Proflame 2 Remote Control System consists of two 2 elements 1 Proflame 2 Transmitter 2 Integrated Fireplace Controller IFC and wiring harness to connect to the gas valve stepper motor battery holder...

Страница 11: ... powered by four 4 AA type batteries The IFC accepts commands via radio frequency from the Transmitter to operate the appliance in accordance with the particular Proflame system configuration The Battery Holder has a three 3 position slider switch that can be set to one of three positions ON Manual Override Remote Remote control or Off The Battery Holder has a reset button at the front right corne...

Страница 12: ...uctions Turn off the Appliance Press the ON OFF Key on the Transmitter The Transmitter LCD display will only show the room temperature and Icon see Figure 9 A single beep from the IFC confirms reception of the command and both the pilot light if the unit is not set to continuous pilot and main burner will turn off Room Thermostat Transmitter Operation The Remote Control can operate as a room therm...

Страница 13: ...ill confirm reception of the command Figure 11 Remote Control s Flame Levels Flame Off Flame Level 1 Flame Level 5 Maximum Flame Level Flame Off Flame Level 1 Flame Level 5 Maximum Flame Level Fan Control The E33 comes with a convection fan that can be controlled with the Transmitter The fan speed can be adjusted thorugh six 6 speeds To control the fan press the MODE key Figure 5 to index to the f...

Страница 14: ...ontrol This function is not used on the E33 and can be disregarded Key lock This function will lock the keys to avoid unsupervised operation To activate this function press the MODE and UP keys at the same time and the a lock will appear see Figure 16 To de activate this function press the MODE and UP Keys at the same time Figure 16 Remote Control Locked 14 ...

Страница 15: ...eep away from the appliance burner when operating the remote system Operating Instructions WARNING Shock Hazard Can cause severe injury or death This device is powered by line voltage Do not try to repair this device In no way is the enclosure to be tampered with or opened Disconnect from line voltage before performing any maintenance CAUTION Property Damage Hazard Excessive heat can cause propert...

Страница 16: ...dust and lint to cling to the glass surface Initial paint curing of the appliance can leave a slight film on the glass The glass will need cleaning after the fireplace has cooled off from the first burn and about two weeks after first burn Use a mild glass cleaner and a soft cloth Abrasive cleaners will damage the glass and painted surfaces Depending on the amount of use the glass should require c...

Страница 17: ...ice person The glass must be purchased from an ENVIRO dealer No substitute materials are allowed Remove the door see page 16 The replacement glass will come with a new gasket installed Remove any silicone remnants from the door Apply high temperature silicone to the two vertical faces of the door and install the new piece of glass with gasket be sure to maintain edge clearances Apply even pressure...

Страница 18: ...e missing contact your dealer distributor or courier company to have them replaced before starting this installation Maintenance And Service Conversion Kit Installation 1 Turn the unit off by pressing the ON OFF Key on the remote and shut off gas supply at the shut off valve upstream of the unit CAUTION The gas supply must be shut off prior to disconnecting the electrical power and before proceedi...

Страница 19: ...n altitude higher than 2000ft 610m it is required to de rate the unit accordingly In the USA The appliance may be installed at higher altitudes Please refer to your American Gas Association guidelines which state the sea level rated input of Gas Designed Appliances installed at elevations above 2000 610 m feet is to be reduced 4 for each 1000 feet 305 m above sea level Refer also to local authorit...

Страница 20: ... installed into masonary or zero clearance fireplaces 20 37 36 35 34 33 32 31 30 1 2 3 4 5 6 7 8 9 10 11 12 M A N T L E H E I G H T F R O M U N I T B O T T O M M A N T L E D E P T H Minimum Mantle Clearances 12 MANTLE Non Combustible Build Out The E33GI E33GID may be installed and vented into any solid fuel fireplace that has been installed in accordance with the National Provincial State and loca...

Страница 21: ... 3 vent and must be fastened directly to the vent with three screws The exhaust vent and air intake are both located on the top of the unit Check periodically that the vents are unrestricted Also ensure that all direct vent pipes have been properly sealed and installed after routine inspection or cleaning The air intake and exhaust pipes must be installed in the correct locations on the top of the...

Страница 22: ... and the exhaust are 3 76mm Measure the height of the chimney beforehand and purchase the appropriate venting Never attempt to over stretch a flexible liner to accommodate the height of the chimney Every joint in the venting must be secured with three 3 The height for the vent must be between 8 ft 2 44 m and 30 ft 9 14 m Install a sealed vent cap to prevent leakage of room air up through chimney T...

Страница 23: ... through chimney The intake and the exhaust are 3 76mm Measure the height of the chimney beforehand and purchase the appropriate venting Never attempt to over stretch a flexible liner to accommodate the height of the chimney Every joint in the venting must be secured with three 3 8 x 3 8 HWH sheet metal screws and an appropriate sealant either silicone or stove cement The flue damper must be fully...

Страница 24: ...y The flue damper must be fully blocked open or removed for installation of the E33 the smoke shelves shields and baffles may be removed if attached by mechanical fasteners Table 5 Vent termination clearances Minimum Clearance Description 3 ft 0 9 m Clearance above the highest point where it passes through a roof surface refer to Figure 29 24 in 0 6 m Clearance above a roof ridge any other portion...

Страница 25: ...vent terminal Slide the Ø3 76mm flex intake liner over the collar secure the flex liner with three 3 sheet metal screws evenly spaced Secure the vent terminal to the chimney using adequate sealant and according to local building codes 10 If the fireplace opening is lower than 24 610 mm remove the vent collar plate from the top of the insert by unscrewing the 5 15 screw located on the center top of...

Страница 26: ...the lower sides or bottom of the firebox in a proper workmanship like manner This access hole must be plugged with non combustible insulation after the gas supply line has been installed Cutting any sheet metal parts of the fireplace in which the gas fireplace insert is to be installed except as tested for the floor is prohibited The included label plate shown below must be permanently attached in...

Страница 27: ...trols label all wires prior to disconnection Wiring errors can cause improper and dangerous operation Verify proper operation after servicing If any of the original wire as supplied with the appliance must be replaced it must be replaced with 18 AWG wire with a temperature rating of at least 105 C Electrical Requirements 27 IFC 50 3312 0 584 325 IFC Main Harness 50 3030 0 584 924 Transmitter TMFSL...

Страница 28: ...orkmanship like manner This access hole must be plugged with non combustible insulation after the gas supply line has been installed A shut off valve is supplied with this unit The appliance and its shut off valves must be disconnected from the gas supply piping system during any pressure testing where the pressure exceeds psig 3 45 KPa or the valve will be damaged Figure 36 Gas connection locatio...

Страница 29: ...tion after completing the required pressure test 29 Pilot Adjustment Screw Manifold Pressure Tap Inlet Pressure Tap Servo Regulator Pilot Solenoid Burner Solenoid Gas IN Adjusting The Pilot Flame does not apply to E33GID models Figure 39 Proper Pilot Flame 375 500 10 13mm Flame Sensor The pilot flow adjustment is set to maximum at the factory and should not need to be adjusted The pilot flame shou...

Страница 30: ...42 3 If installing with riser s the Base Shelf is to be fastened to the riser s with one T 20 screw at each end of the back Figure 42 Combining 2 Base Shelf Riser Figure 43 Installing Base Shelf onto Riser see Figure 43 4 The leveling legs on the E33 may need to be adjusted to match the height of the riser and shelf 5 Center the Base Shelf assembly in front of the unit flush with the bottom of the...

Страница 31: ...ble Surround 3 If desired offset the measurements by approximately 1 8 3mm to the inside this will allow for the panel to be placed just inside the fireplace opening for a cleaner appearance 4 Cut along the preferred line from direct measurements of offset and remove any sharp edges 5 The panel can be touched up with a high temperature metallic black paint available from your dealer INSTALLATION 1...

Страница 32: ...erature before beginning this installation Height Width 3 Sided Surround 26 1 2 673 mm 44 1 8 1121 mm Table 8 Surround Dimensions Please check components supplied with this kit If components are missing or have been damaged contact your dealer distributor or courier company before starting this installation IMPORTANT The panel must not seal ventilation openings in the fireplace INSTALLATION If Ins...

Страница 33: ...ass material if installed 4 Use the following steps to remove the liners and the burner tray NOTE Follow the steps in the reverse order for reassembly WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury Figure 50 Remove the side panel retainer clips which secu...

Страница 34: ...for a 0 250 0 375 thin layer to cover the area shown Ensure that the pilot flame slot remains clear of any glass Figure 53 Glass tray burner with glass for Rock Burner If the Rock burner option is being installed use the supplied glass media and fill the up the burner area only as shown in Figure 53 Only fill until the glass is flush with the bunrner tray much less glass is used with this set up S...

Страница 35: ... LED indicator will blink one 1 time in intervals 3 Parasitic Pilot Flame the LED indicator will blink two 2 times in intervals 4 System Lock out the LED indicator will blink three 3 times in intervals Additional Ignition Information 1 The Proflame2 IFC will try two 2 times for ignition 2 Each try for ignition will last approximately 60 seconds 3 The wait time between the two tries is approximatel...

Страница 36: ...he pilot will automatically turn off when the burner has not been used for 7 consecutive days Re light pilot to reset the counter Problem with Flame Sensor circuit Check for proper connection of the Flame Sensor to the IFC board Check pilot for full flame impingement around Flame Sensor If flame is too small check gas pressure adjust pilot rate screw check pilot head for damage Ensure the ground w...

Страница 37: ...re Flame lifting Leak in vent pipe Check for leaks in vent connections Improper vent configuration Check vent configuration with manual Check positioning of baffle plate Terminal may be re circulating flue gases Check to see if terminal is on correctly May need to install high wind termination cap Contact dealer Blue Flames The heater has just been started Normal during start up flame will yellow ...

Страница 38: ...er 50 3314 River Rock Set 50 3838 8 885 Proflame IPI Valve NG 50 2682 9 Proflame 2 Battery Holder 0 584 103 50 3204 Battery Holder Wire Harness 0 584 922 50 3203 10 Proflame 2 IFC 50 3791 IFC Wire Harness 0 584 924 50 3030 IFC ON OFF Jumper Only 50 3205 11 Proflame 2 Transmitter TMFSLA 50 3265 12 E33 Door Complete 50 2522 13 E33 Glass C W Gasket 28 5 X 18 50 2523 14 Dual Bulb Door Gasket 10ft 50 6...

Страница 39: ...Parts Diagram Components 1 2 17 8 10 5 6 7 16 9 18 14 13 12 15 11 4 3 39 ...

Страница 40: ...fety screen mesh Exclusions An expanded list of exclusions is available at www enviro com help warranty html This warranty does not cover Damage as a result of improper usage or abuse Damage caused from over firing due to incorrect setup or tampering Damage caused by incorrect installation To the Dealer Provide name address and telephone number of purchaser and date of purchase Provide date of pur...

Страница 41: ...__________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy DIRECT VENT NATURAL GAS NAT PROPANE LPG INLET GAS PRESSURE _________in WC MAIN BURNER ORIFICE __________ DMS PILOT ORIFICE _________OR________in diam INSTALLER S SIGNATURE _______________________________...

Отзывы: