Send Type
The output for this stream can be sent either by
Broadcast
messages sent to the entire IP network or
to a specific
IP
address on the network.
IP Address
Where a specific IP address is required, it should be entered in the standard IP version 4
nnn.nnn.nnn.nnn
format (where nnn is a decimal number between 0 and 255. Eg. 172.16.103.254).
Channel Range
The channel range is the block of DMX channels from the current data stream that will be recorded
and relayed as part of the Show.
Any continuous range of DMX512 channel numbers [1-512] may be entered for the stream.
DMX USB
Enttec's DMX USB Pro interface is a bi-directional DMX to USB interface for a single DMX512
universe. DMX USB Pro units can be connected to any or all of the four USB ports on the rear panel
of the Streamer Engine, allowing direct DMX512 input and output from the E-Streamer.
Device ID
Each DMX USB Pro interface is assigned a Device ID when connected to the Streamer Engine.
(See
).
USB Device Identification on page 38
The
Device ID
selected for the stream should correspond to a
device already connected to the E-Streamer.
Channel Range
The channel range is the block of DMX channels from the current data stream that will be recorded
and relayed as part of the Show.
Any continuous range of DMX512 channel numbers [1-512] may be entered for the stream.
Save Stream
The
Save Stream
button saves all configuration information for the current stream.
Remove Stream
The
Remove Stream
button deletes all configuration data for the current stream.