1.
Hold the gauge so that it stays horizontal against
the flange.
• Perform these steps before mounting NMS8x on the
nozzle.
• Do not tilt NMS8x after removing the displacer holder.
2.
Cut the fixing bands [2].
3.
Remove the displacer holder [3] and packing
material of the displacer.
4.
Mount NMS8x on the nozzle.
• Make sure that the measuring wire hangs vertically.
• Confirm that there are no kinks or other defects in the
measuring wire.
5.
Remove screws and M6 bolts [6] (M10 bolts for
stainless steel housing) to remove the drum
housing cover [5].
Be sure not to lose the O-ring and the fixing bolts for the
cover of the drum housing.
6.
Loosen two screws and remove the wire drum
stopper [4].
7.
Remove the tape [1] from the wire drum carefully. • Remove the tape by hand to avoid damaging the wire
drum.
• Make sure that the measuring wire is wound so that it
fits correctly in the grooves.
8.
Mount the drum housing cover.
Confirm that the O-ring is in the drum housing cover.
9.
Turn on the power of NMS8x.
Sensor, reference, and drum calibration steps are
not required because they are all performed prior to
delivery.