Proservo NMS80
Commissioning
Hauser
59
Submenu: Setup → Advanced setup → Input/output → HART devices → HART Device(s)
Parameter
Meaning / Action
Output pressure
• If the device measures a pressure: Select which of the HART variables (PV, SV, TV or QV)
contains the pressure.
• Otherwise: Keep the factory setting:
No value
Output density
• If the device measures a density: Select which of the HART variables (PV, SV, TV or QV)
contains the density.
• Otherwise: Keep the factory setting:
No value
Output temperature
• If the device measures a temperature: Select which of the HART variables (PV, SV, TV or
QV) contains the temperature.
• Otherwise: Keep the factory setting:
No value
Output vapor
temperature
• If the device measures the vapor temperature: Select which of the HART variables (PV,
SV, TV or QV) contains the vapor temperature.
• Otherwise: Keep the factory setting:
No value
Output level
• If the device measures a level: Select which of the HART variables (PV, SV, TV or QV)
contains the level.
• Otherwise: Keep the factory setting:
No value
1)
There is a
HART Device(s)
submenu for each connected HART device.
2)
This setting can be skipped for a connected Prothermo NMT5xx and NMT8x or Micropilot FMR5xx as for these
devices the type of measured value is identified automatically.