11 Appendix
Mycom S CLM 153
108
EHauser
PARAM
Back to
return field
Data logger1/2
Meas.value PV K1
Function off
PCS time
PCS K1 off
Rec.polaris.K1 off
PCS K2 off
Rec.polaris.K2 off
Select
Data logger
Check
Controller
configuration
Limit functions
Chemoclean
(only with
connected system,
see below)
Select
Data logger
Measuring interval
Data logger 1 /
Data logger 2
Enter
measuring interval
00005s
(2 … 36000s)
C07-CLM153xx-19-06-08-en-002.EPS
PARAM
Set up 1
Controller values
Manual operation
Quick Setup
Set up 2
»Return field«:
press the PARAM
key to return to
the highlighted
fields.
= Code entry required
Back to
return field
Back to
return field
Back to
return field
Electrodes/dosing
point intervals
LVB: 0,5 m
LVS: 0,5 m
LVE: 1,5 m
With resistance
input:
Move valve to
y=100 % and
enter current
resistance
With segmented:
Set point
Start neutral zone
End neutral zone
Optimisation point 1/2
Control point 1/2
Configuration
LC 1/2/3/4/5:
Switch-on delay: 0 s
Switch-off delay: 0 s
Alarm
threshold: 1000mS
Configuration of
external hardware:
Type
Sensors
Feedback
(Menu option
is hardware
dependent)
Characteristic
With resistance
input:
Select range
0 ... 1 kW
0 ... 10 kW
Select characteristic
type:
linear
segmented
Select for
configuration:
Limit value sensor 1
...
Limit value sensor 5
Selection Control
2 outputs
(=2 relays)
1 output
(= current output2)
(when relays and
current output defined)
Control using
Pulse length
Pulse frequency
3-point step contr.
Current output
With resistance
input:
Move valve to
y=0 % and enter
current resistance
With linear:
Set point
Start neutral zone
End neutral zone
Kr 1
Kr 2 (only 2-sided)
Configuration
LC 1/2/3/4/5
Function: off
Assignm.: PV K1
Switch-on pt.: 1000mS
Switch-off pt.: 1000mS
Control
Down: Impulse length
Up: Impulse length
Dosing via
Current output 2:
0 ... 20 mA
4 ... 20 mA
single
batch/inline
dual
batch/inline
Selection process
type:
batch 1-sided up
batch 1-sided down
batch 2-sided
inline 1-sided up
inline 1-sided down
Activating Controller
function
off
on
(contr. must have been
configured)
Flowmeter
volume flow
Unit
0 mA value: xxx
20 mA value: xxx
Unit
Nominal diameter: 1/12
Flowmeter
Mycom connection
Current output 2
0 ... 20 mA
4 ... 20 mA
Relay selection
Pulse length:
Relay: n.c.
Period: 010.0s
tE min: 000.4s
Relay selection
3-point step contr.:
+Relay: Rel. 1
–Relay: Rel. 2
Motor running time
XSD 00.00%
Relay selection
Pulse frequency:
Relay: n.c.
Max. pulse
frequency
Up/down dosing
Relay selection
3-point step controller:
+Relay: Rel. 1
–Relay: Rel. 2
Motor running time
Position feedback on
Up/down dosing
Relay selection
Impulsfrequenz:
Relay: n.c.
Max. pulse frequency
Back to
return field
Current output 2:
Assign
100% dosing
0/4 mA
20 mA
Back to
return field
Disturbance
feedforward
Function on
Limit 050.0
Kdist.=1: 050.0
Kmax: 1.7
Kdisconnect: 1.0
With current input:
Select range
yR=0 ... 100 %
4 ... 20 mA
20 ... 4 mA
With current input:
Move valve to
y=0 % and
enter current
resistance
Process speed
(only linear)
Slow
Standard
Fast
User
Parameter:
Kr1: 1000mS (only lin.)
Kr2: 1000mS (only lin.)
Tn1: 000.0
Tn2: 000.0
Tv1: 000.0
Tv2: 000.0