Transformer 

Article no: 32-3422 • Model: SET105R

Please read the entire instruction manual be-
fore using and save it for future reference.

Description

-  Transformer for 12 V halogen bulbs. 

Comes with short connection cables (15 
cm) without connectors.

-  The transformer has a soft-start feature 

which gradually increases the current after 
it is turned on.

-  Built-in thermal sensor which cuts the 

power if the transformer overheats.

-  An electronic safety circuit turns the 

transformer off if the secondary coil short-
circuits, overheats or if the transformer is 
used without any load. When the fault has 
been rectified the transformer can be used 
again.

Safety and Assembly

-  The transformer conforms to both 89/336/

EEC Directive regarding electromagnetic 
compatibility and 72/23/EEC Low Voltage 
Directive.

-  Permanent installation should only be 

carried out by a qualified electrician.

-  For indoor use only.
-  The primary cable must be at least 0.75 

mm² and the secondary cable between 
0.75 mm² and 1.5 mm².

-  To prevent high frequency power supply 

interference, do not place the transformer 
or its cables close to other electrical 
cables.

-  The transformer should be placed as 

close to the halogen lights as possible.  
However not closer than 30 cm because 
of the heat from the lights.

-  Make sure the transformer has adequate 

ventilation and the ambient temperature 
does not exceed 40°C.

Specifications

Primary voltage: 

230 V, 50 Hz

Secondary voltage: 

11.6 V~rms

Power: 

35-105 W

Current: 

0.46 A

Housing temperature:  85ºC (max)
Ambient temperature:  -20ºC to + 40ºC
Overheating protection: Thermal sensor
Primary cable: 

H03VVH2-F 2x0.75 mm²

Secondary cable: 

1-2 cables, 

 

0.3-4.0 m long or 

 

3 cables, 

 

0.3-3.0 m long or 

 

4-6 cables, 

 

0.3-2 m long

ENGLISH

Ver

. 200712

Содержание SET105R

Страница 1: ...Directive regarding electromagnetic compatibility and 72 23 EEC Low Voltage Directive Permanent installation should only be carried out by a qualified electrician For indoor use only The primary cable must be at least 0 75 mm and the secondary cable between 0 75 mm and 1 5 mm To prevent high frequency power supply interference do not place the transformer or its cables close to other electrical ca...

Страница 2: ...v 89 336 EEC beträffande elektromagnetisk kompatibilitet och med lågvoltsdirektivet 72 23 EEC Fast installation får endast anslutas av behörig elektriker Endast för inomhusbruk Primärkablen ska vara minst 0 75 mm och sekundärkabeln mellan 0 75 mm och 1 5 mm För att förhindra högfrekvensinkopplingar i nätet drag inte utgångskablarna och transformatorn nära sladdar med nätspänning Transformatorn ska...

Страница 3: ...treffende elektromagnetisk kompatibilitet og med lavvoltsdirektivet 72 23 EEC Fast installasjon må kun kobles av sertifisert elektriker Kun for innendørs bruk Primærkabelen skal være minst 0 75 mm og sekundærkabelen mellom 0 75 mm og 1 5 mm For å forhindre høyfrekvensinnkoblinger i nettet dra ikke utgangskablene og transformatoren nær ledninger med nettspenning Transformatoren skal monteres så nær...

Страница 4: ...irektiivien 89 336 EEC elektromagneettinen yhteensopivuus ja 72 23 EEC pienjännitedirektiivi mukaisesti Kiinteän asennuksen saa suorittaa ainoastaan sähköasentaja Vain sisäkäyttöön Ensiökaapelin tulee olla vähintään 0 75 mm ja toisiokaapelin 0 75 mm 1 5 mm Verkon suurtaajuuskytkentöjen välttämiseksi ulostulokaapeleita ja muuntajaa ei saa vetää verkkojännitejohtojen lähelle Muuntaja tulee asentaa m...

Отзывы: