Technical data (cable and housing) and product structure:
For connection of the remote display FHX40 use the cable which fits the communication version of
the respective instrument.
Max. cable length
20 m (65 ft)
Temperature range
-30 °C...+70 °C (-22 °F...158 °F)
Degree of protection
IP65 acc. to EN 60529 (NEMA 4)
Materials
Housing: AlSi12; cable glands: nickle plated brass
Dimensions [mm] / [inch]
122x150x80 (HxWxD) / 4.8x5.9x3.2
Approval:
A
Nn-hazardous area
1
ATEX II 2 G EEx ia IIC T6, ATEX II 3D
S
FM IS Cl.I Div.1 Gr.A-D
U
CSA IS Cl.I Div.1 Gr.A-D
N
CSA General Purpose
K
TIIS ia IIC T6 (in preparation)
Cable:
1
20m/65ft; for HART
5
20m/65ft; for PROFIBUS PA/FOUNDATION Fieldbus
Additional option:
A
Basic version
B
Mounting bracket, pipe 1"/ 2"
FHX40 -
Complete product designation