Operation options
Deltabar PMD78B HART
40
Hauser
7.5.2
FieldCare
Function scope
FDT-based plant asset management tool from Hauser. FieldCare can configure all
smart field devices in a system and helps you manage them. By using the status
information, FieldCare is also a simple but effective way of checking their status and
condition.
Access is via:
• CDI service interface
• HART communication
Typical functions:
• Parameterization of transmitters
• Loading and saving device data (upload/download)
• Documentation of the measuring point
• Visualization of the measured value memory (line recorder) and event logbook
For additional information about FieldCare, see Operating Instructions BA00027S
and BA00059S
7.5.3
DeviceCare
Function scope
Tool for connecting and configuring Hauser field devices.
Together with the device type managers (DTMs) DeviceCare presents a convenient,
comprehensive solution.
For details, see Innovation Brochure IN01047S
7.6
HistoROM
If the electronic insert is replaced, the stored data (except the event list) are transferred by
unplugging the HistoROM module and plugging it into the new electronic insert. The
device does not work without HistoROM.
The device serial number is saved in the HistoROM. The electronics serial number is saved
in the electronics.