Deltabar FMD72
Diagnostics and troubleshooting
63
Diagnostics event
Cause
Corrective measure
Code
Description
F162
Sensor conn. HP
Sensor conn. LP
• Electromagnetic effects outside the permitted range.
This message appears for a short time only.
• Sensor module defective.
• Check sensor cable
• Replace sensor
• Contact Endress
+Hauser Service
F163
Sensor conn.
• Cable connection between sensor modules HP and LP
interrupted.
• Sensor module defective (slave).
• Electromagnetic effects outside the permitted range.
This message appears for a short time only.
• Restart device
• Check the sensor
module cable
• Contact Endress
+Hauser Service
F164
Sensor sync.
• The sensor modules cannot be synchronized with each
other.
• Electromagnetic effects outside the permitted range.
This message appears for a short time only.
• Sensor module(s) defective.
• Restart device
• Replace sensor module
• Contact Endress
+Hauser Service
F165
Sensor assignment
The assignment of the transmitter to sensor module LP or
HP is unknown (e.g. after changing the sensor module).
See also (
66) "Replacement of sensor modules".
• Connect transm. set.
• Restart device
• Contact Endress
+Hauser Service
F261
Electronics module
• Main electronics defective.
• Fault in the main electronics.
• Sensor module defective.
• Restart device
• Replace electronics
F282
Data storage
• Main electronics defective.
• Fault in the main electronics.
• Replace electronics
• Restart device
F283
Memory content
• Main electronics defective.
• Electromagnetic effects are greater than specifications
in the technical data.
• The supply voltage is disconnected when writing.
• An error occurred when writing.
• Perform a reset
• Replace electronics
F411
Upload/download
• The file is defect.
• During the download, the data are not correctly
transmitted to the processor, e.g. because of open cable
connections, spikes (ripple) on the supply voltage or
electromagnetic effects.
• Repeat download
• Use other file
• Perform a reset
F510
Linearization
The linearization table is being edited.
• Conclude entries
• Select "linear"
F511
Linearization
The linearization table consists of less than 2 points.
• Table too small
• Correct table
• Accept the table
F512
Linearization
The linearization table is not monotonic increasing or
decreasing.
• Tab. not monotonic
• Correct table
• Accept the table
F841
Sensor range
• Overpressure or low pressure present.
• Sensor module defective.
• Check the pressure
value
• Contact Endress
+Hauser Service
F882
Input signal
External measured value is not received or displays a
failure status.
• Check the bus
• Check source device
• Check the setting
F945
Pressure limit LP
• The configured overpressure or underpressure limit of
sensor module LP is exceeded.
• Sensor module LP defective.
• Check the pressure
value
• Change pressure limit
value
• Contact Endress
+Hauser Service