13.3 Process
Process temperature range
Standard device (without diaphragm seal)
NOTICE
The permitted process temperature depends on the process connection, process seal,
ambient temperature and the type of approval.
‣
All the temperature data in this document must be taken into consideration when
selecting the device.
0
32
20
68
40
104
60
140
80
176
100
212
125
257
100
212
80
176
70
158
40
104
20
68
0
32
-20
-4
-40
-40
T
a
T
p
°C
°F
°C
°F
A0043292
5
Values apply for vertical mounting without insulation.
T
p
Process temperature
T
a
Ambient temperature
Diaphragm seal fill fluid
Fill fluid
P
abs
= 0.05 bar (0.725 psi)
P
abs
≥1 bar (14.5 psi)
Silicone oil
–40 to +180 °C (–40 to +356 °F)
–40 to +250 °C (–40 to +482 °F)
High-temperature oil
–20 to +200 °C (–4 to +392 °F)
–20 to +400 °C (–4 to +752 °F)
Low-temperature oil
–70 to +120 °C (–94 to +248 °F)
–70 to +180 °C (–94 to +356 °F)
Vegetable oil
–10 to +160 °C (+14 to +320 °F)
–10 to +220 °C (+14 to +428 °F)
Inert oil
–40 to +100 °C (–40 to +212 °F)
–40 to +175 °C (–40 to +347 °F)
1)
Permitted temperature range at p
abs
= 0.05 bar (0.725 psi) (observe temperature limits of the device and the system!)
2)
Permitted temperature range at p
abs
≥1 bar (14.5 psi) (observe temperature limits of the device and the system!)
3)
325 °C (617 °F) at ≥1 bar (14.5 psi) absolute pressure
4)
350 °C (662 °F) at ≥1 bar (14.5 psi) absolute pressure (max. 200 hours)
5)
400 °C (752 °F) at ≥1 bar (14.5 psi) absolute pressure (max. 10 hours)
6)
150 °C (302 °F) at ≥1 bar (14.5 psi) absolute pressure
7)
175 °C (347 °F) at ≥1 bar (14.5 psi) absolute pressure (max. 200 hours)
Fill fluid
Density
kg/m
3
Silicone oil
970
High-temperature oil
995
Low-temperature oil
940