Intended Use
The differential temperature controller may be used exclusively as controller for the con-
trol of solar thermal plants. It must be operated within the scope of all the specifications
described. Installation and set-up of the controller may only be performed by specialists.
The fitter must have read and understood the operating manual.
The fitter explains all the relevant functions to the operator.
For operation, it is essential that the housing is closed and free of damage.
Scope of supplies
1 Differential temperature controller smart Sol plus
1 Instruction manual
Differential temperature controller smart Sol plus
Type of mounting
Wall-mounting
Housing
Plastics, in several parts
Mode of operation
Type 1
Type of protection
IP 20
Dimensions Width x Height x Depth [mm] 218 x 218 x 51
Weight [g] Basic version
725
Storage/operating temperature [°C]
0-40, non-condensation
Handling
via rotary encoder and pushbuttons
Display
TFT colour display 70 x 53 mm, backlit
Connection to power supply
Design
3 spring-type terminals PE, N and L
Service voltage [VAC]
85-265
Line frequency [Hz]
50 ±1%
Auxiliary consumption typ. [W]
1.25
Power consumption max. [W]
3.1
Fuse
Micro fuse, type 5 x 20 mm, T4A/250 V
Rated pulse voltage [V]
2500
Max. cross sections to be connected
Cable end sleeve:
0.25 to 0.75 mm
2
Single-wire
0.50 to 1.50 mm
2
Fine-wired
0.75 to 1.50 mm
2