72
Operation mode
›1.3.3 Holiday funct...‹ appears.
Here, you enter the time of your next
holiday. “Holiday” means that the
heating/
warm water plant is not used in sum-
mer.
In this case, the controller will adapt
control for the specified period so that
overheating of the plant is prevented.
First select the subitem ›Start‹,
then ›End‹ by pressing ›OK‹.
›Edit‹ appears.
Here, the dates of your absence are
entered. Return to ›1.3 Basic func-
tions‹.
Continue with ›Delta T control‹.
›1.3.5 dT control‹ appears.
Here, parameters of the
controller can be changed.
The factory settings of the
smart Sol plus can be used
for almost all plants.
Ask a fitter before making
changes at this point.
Return to ›1.3 Basic functions‹.
Continue with ›Fixed T control‹.
Start of holiday
End of holiday
19.07.2013
02.08.2013
1.3.3 Holiday function
25.08.2012
10:26
Start of holiday
Restore last value
Factory settings
19.
07.2013
Edit
25.08.2012
10:26
dT-ON 1
dT-OFF 1
8.0k
4.0k
1.3.5 dT control
25.08.2012
10:27