41978-2-0321
Page 63
IPI ELECTRONIC SYSTEM WIRING DIAGRAM
(GND)
PILOT
GAS CONTROL
VALVE
ELECTRONIC
CONTROL MODULE
BATTERY HOLDER
BATTERY
BACK-UP
RED
BLACK
RED
BLACK
GREEN
WHITE
BLUE
WHITE
ORANGE
GREEN
YELLOW
ORANGE
WHITE
AC/DC
POWER ADAPTOR
REMOTE RECEIVER
(OPTIONAL)
+ ON
REMOTE
- OFF
BLACK
WHIT
E
ON/OFF
SWITCH
OR
If any of the original wire as supplied with this unit must be replaced,
it must be replaced with equivalent gauge and temperature rated
wire.
This appliance is only for use with the type of gas indicated on the
rating plate and may be installed in an aftermarket, permanently
located, manufactured (mobile) home where not prohibited by
local codes. This appliance is not convertible for use with other
gases, unless a certified kit is used.
WARNING
Improper installation, adjustment, alteration, service or
maintenance can cause property damage, personal injury
or loss of life. Installation and service must be performed
by a qualified installer, service agency or the gas supplier.
WARNING
Electrical Grounding Instructions
This appliance is equipped with a three-prong (grounding)
plug for your protection against shock hazard and should
be plugged directly into a properly grounded three-prong
receptacle. Do not cut or remove the grounding prong from
this plug. The AC/DC adapter, if used, has a 2-prong plug
which does not require an additional ground.
CAUTION
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation.