
41978-2-0321
Page 12
SPECIFICATIONS
DVL36BP
DVL46BP
Natural
Propane
Natural
Propane
Input BTU/Hr Maximum
25,000
25,000
30,000
31,000
Input BTU/Hr Minimum
18,000
20,000
22,000
25,000
KWH (Maximum)
7.33
7.33
8.79
9.09
KWH (Minimum)
5.28
5.86
6.45
7.33
Orifice
2.35mm (P294)
#53 (P214)
#37 (P213)
1.65mm (P250)
Air Shutter Opening
1/16"
Fully Open
1/16"
Fully Open
Gas Inlet Shut-Off Valve (Pipe)
1/2" NPT
1/2" NPT
1/2" NPT
1/2" NPT
Vent Size
4 x 6-5/8
4 x 6-5/8
4 x 6-5/8
4 x 6-5/8
NOTICE:
Air shutter settings are factory minimum settings. Some venting configurations may require minor air shutter adjustments for
optimum performance.
GAS SUPPLY PRESSURES (Dimensions In Inches Water Column - W.C.)
Gas Type
Maximum
Minimum
Manifold
Natural
14
4.5
3.5
Propane
14
11
10