ELECTRICAL CONNECTIONS (CONT’D)
CONTROL MODULE POSITIONING (IP ONLY)
The IP Control Module is attached to the inside of the bottom face
with Velcro during shipping. Prior to operating the fireplace, the
Control Module must be unfastened from the Velcro and relocated
to the open space beneath the fireplace.
See Figures 22 and 23.
Set the Control Module as far to the right as the pilot and valve
connections will allow, and toward the front.
Route the AC adapter wire along the inside of the bottom face.
Use the self-adhesive wire clips included in the hardware pack to
keep the wire away from the firebox.
See Figure 23.
These clips
may also be used to manage the Accent Light Kit electrical cord
(See Light Kit installation section).
2X4 RECTANGULAR SUPPORT
MODULE
LOCATION
Figure 22
SCREEN
BOTTOM FACE
AC ADAPTER WIRE
JUNCTION BOX
WIRE CLIP
Figure 23
BATTERY HOLDER POSITIONING
Place the Battery Holder for the battery backup in the front right
corner of the open space beneath the fireplace.
See Figures 24.
2X4 RECTANGULAR SUPPORT
BATTERY
HOLDER
LOCATION
Figure 24