SI-EtherCAT User Guide
41
Issue Number: 2
Sa
fe
In
M
El
G
P
D
Ad
va
Pa
ra
Di
G
In
6.4
Additional position loop scaling
For applications where different feedback devices with different resolutions are required for the
drive velocity and position loops, this object can be used to apply a scaling factor to the position
loop output value.
Table 6-28 Additional position loop scaling
0x3004
Additional position loop scaling
Sub-index 0
Access: RO
Range: N/A
Size: 1 byte
Unit: N/A
Default: 2
Type:
USINT
Description:
The number of the last sub-index in this object.
Sub-index 1
Access: RW
Range: -2
31
to +2
31
-1
Size: 4 bytes
Unit: N/A
Default: 1
Type:
DINT
Description:
The additional position loop output scaling numerator
Sub-index 2
Access: RW
Range: -2
31
to +2
31
-1
Size: 4 bytes
Unit: N/A
Default: 1
Type:
DINT
Description:
The additional position loop output scaling denominator