SI-EtherCAT User Guide
97
Issue Number: 2
Saf
ety
Intro
Mech
El
Get
tin
Pr
Dr
A
Par
amet
er
D
G
In
10.5
Option module trips
Table 10-9 Option module trips
10.6
Updating SI-EtherCAT firmware
The latest SI-EtherCAT firmware is available from your local Control Techniques Drive Centre or supplier.
To upload firmware to SI-EtherCAT a copy of Unidrive M Connect and a suitable communications lead for
the option module's host drive is required.
10.7
Switching frequency
In applications where greater synchronization is required, it is suggested that the drive's automatic
switching frequency option is switched off. If automatic frequency switching is required, then the
network will continue to operate, however the synchronization jitter may increase for a short time
when the switching frequency changes. To disable the drive's automatic switching frequency
control, set the drive Pr
05.035
to Disabled (1).
10.8
Sync Task Orun trips
If SI-EtherCAT cannot complete the assigned tasks within its 250 µs Synchronous Task, a Sync
Task Orun trip will be initiated; a Sync Task Orun trip indicates that the user is trying to accomplish
too much within the Synchronous task. The user can influence the Synchronous Task by reducing
the amount of cyclic data, or disabling drive control CiA402. To disable drive control set the
Pr
S.00.033
to On (1), and perform an option reset via Pr
S.00.007
.
Value
(Pr 10.070)
Display Text
Description
200
SW fault
Software Fault
201
BG Orun
Background task overrun
202
FW invalid
Invalid firmware for hardware version
203
Drv unknown
Unknown drive type
204
Drv unsupported
Unsupported drive type
205
Mode unknown
Unknown drive mode
206
Mode unsupported
Unsupported drive mode
207
FLASH corrupt
Corrupted non-volatile FLASH
208
Dbase init
Database initialisation error
209
FS init
File system initialisation error
210
Memory alloc
Memory allocation error
211
Filesystem
File system error
212
Configuration
Configuration file save error
213
OHt
Overheated
214
TO drv
The drive has not responded within the watchdog
period
215
ECMP
eCMP communication failure
216
TO ECMP slot 1
eCMP communication to slot 1 timeout
217
TO ECMP slot 2
eCMP communication to slot 2 timeout
218
TO ECMP slot 3
eCMP communication to slot 3 timeout
219
TO ECMP slot 4
eCMP communication to slot 4 timeout
220
Reserved
Reserved
221
ERROR_MISSING_FACTORY_SETTINGS Factory settings file is missing
222
ERROR_FUNCTIONAL_TEST
Functional test failed
223
ERROR_CONFIG_FILE_LOAD
Configuration file failed to load
224
ERROR_POWER_ON_TEST
Power on self test failed
225
ERROR_RUNTIME_CONFIG
Runtime configuration error