EtherCAT AL status codes
Table 10-10 shows the possible AL (Application Layer) status codes returned to the EtherCAT
master controller during configuration or operational mode.
Table 10-10 Application Layer status codes
Code
(0x)
Meaning
Description
Comment
0000
No error
No error
0001
Unspecified error
No error code has been defined
Contact supplier
0002
No memory
Insufficient memory for operation
Contact supplier
0011
Invalid requested state
changed
Requested state change is
invalid
Follow the EtherCAT State
Machine sequence to change
state
0012
Unknown requested state
change
Requested state change is
unknown
Use only the EtherCAT State
Machine state values
0013
Boot state not supported
Device does not support BOOT
state
Contact supplier
0014
No valid firmware
Downloaded firmware
application file is invalid
Download correct firmware
application file
0015
Invalid mailbox configuration
Mailbox configuration differs
from expected settings
Replace network description
file
with the correct file for device
0016
Invalid mailbox configuration
Slave device changed but
network configuration is
unchanged
Replace previous network
description of old slave with the
one of the new slave.
0017
Invalid Sync Manager
configuration
PDO length, address or
direction mismatch
Issue a re-calculation of the
EtherCAT configuration.
0018
No valid inputs available
No valid inputs available on
Slave device
Check slave input objects
0019
No valid outputs available
Slave device cannot receive
valid output values
Check slave output objects
001A
Synchronization error
Too many RxPDO toggle errors
have occurred
Check configuration
001B
Sync Manager watchdog
No process data received within
specified timeout
Check process data
configuration
001C
Invalid Sync Manager Types
Specified Sync Manager type is
invalid
Use correct Sync Manager
001D
Invalid output configuration
Sync Manager for output
process data is invalid
Use correct Sync Manager
001E
Invalid input configuration
Sync Manager for input process
data is invalid
Use correct Sync Manager
001F
Invalid watchdog
configuration
The watchdog configuration is
invalid
Check watchdog setting
0020
Slave needs cold restart
Slave device requires a cold
restart or power cycle
Restart the slave device