SI-EtherCAT User Guide
99
Issue Number: 2
Saf
ety
Intro
Mech
El
Get
tin
Pr
Dr
A
Par
amet
er
D
G
In
0021
Slave needs INIT
Slave application requests INIT
state
Re-initialise the slave device
0022
Slave needs PREOP
Slave application requests,
PREOP state
Instruct slave device to enter
PREOP state
0023
Slave needs SAFEOP
Slave application requests
SAFEOP state
Instruct slave device to enter
SAFEOP state
0024
Invalid input mapping
Invalid input mapping object
Check slave input mapping
0025
Invalid output mapping
Invalid output mapping object
Check slave output mapping
0026
Inconsistent settings
General settings mismatch
Check configuration settings
0027
Freerun not supported
Freerun not supported on slave
0028
Synchronization not
supported
Synchronization not supported on
slave
0029
Freerun needs 3 Buffer Mode
Sync Manager requires 3 Buffer
Mode to run
002A
Background Watchdog
Background task watchdog
activated
002B
No valid inputs and outputs
Slave device does not provide
valid inputs and outputs
002C
Fatal Sync error
The hardware synchronization
signal has stopped
Set master to INIT and back to
OP so that the DCs are
initialized again.
002D
No Sync error
Hardware synchronization signal
not detected
0030
Invalid DC SYNC
configuration
Distributed Clocks configuration is
invalid
Check DC configuration
0031
Invalid DC Latch configuration
Distributed Clocks Latch
configuration is invalid
Check DC configuration
0032
PLL error
Master not synchronized, at
least one DC event received
Check wiring and
synchronization settings
0033
DC Sync IO error
Multiple sync errors: At least one
sync signal was received but the
slave is no longer synchronized
Check network jitter
Increase cycle time
Use Distributed Clocks scheme
0034
DC Sync timeout error
Multiple sync errors: Excessive
Sync Manager events missed
Check DC configuration
0035
DC invalid sync cycle time
DC sync cycle time is invalid
Check DC configuration
0036
DC Sync0 cycle time
DC Sync0 cycle time invalid for
application
Check DC configuration
0037
DC Sync1 cycle time
DC Sync1 cycle time invalid for
application
Check DC configuration